Close Menu
  • News
  • Industry
  • Solar Panels
  • Commercial
  • Residential
  • Finance
  • Technology
  • Carbon Credit
  • More
    • Policy
    • Energy Storage
    • Utility
    • Cummunity
What's Hot

Mitsubishi Electric Trane announces new heat pump line for hydronic heating – SPE

March 6, 2026

Origis is developing a 413 MW solar portfolio in West Texas

March 6, 2026

New Jersey expands state community solar program by 3 GW

March 6, 2026
Facebook X (Twitter) Instagram
Facebook X (Twitter) Instagram
Solar Energy News
Friday, March 6
  • News
  • Industry
  • Solar Panels
  • Commercial
  • Residential
  • Finance
  • Technology
  • Carbon Credit
  • More
    • Policy
    • Energy Storage
    • Utility
    • Cummunity
Solar Energy News
Home - Technology - Combining PV-powered heat pumps with district heating in buildings with Multi-apartment-PV Magazine International
Technology

Combining PV-powered heat pumps with district heating in buildings with Multi-apartment-PV Magazine International

solarenergyBy solarenergyJuly 3, 2025No Comments4 Mins Read
Facebook Twitter Pinterest LinkedIn Tumblr Email
Share
Facebook Twitter LinkedIn Pinterest Email

An international research group has investigated how PV-driven heat pumps and district heating can be combined to heat a building with several apartments in Sweden and has discovered that of the three combinations they evaluated, dependent on heat pumps, since the primary heat source was the “most advantageous solution” in terms of operational costs and environment.

July 3, 2025
Lior Kahana

A European research group has conducted a study into the performance of a hybrid PV -driven heat pump (HP) and district heating (DH) system in a building with several apartments. It was simulated via Trnsys software, based on the real parameters of an apartment building in Gothenburg, Sweden.

“The building is a 5 -storey test bed, called ‘HSB Living Lab’, with 29 apartments. It can be assumed that the building is always occupied, even during the summer holidays,” the team said. “The weather in Gothenburg is characterized by maritime moderate with cool summers and mild winters. The annual rainfall is around 850 mm, evenly spread throughout the year. The daylight takes between 6 – 18 hours a day, depending on the season.”

The heating system consists of two air-water heat pumps, district heating and an extra electric heater. Each heat pump has a total airflow speed of 1500 l/s and a nominal heating capacity of 9.8 kW. The electrical consumption of the compressor is 2.31 kW and the fan is 0.18 kW. The heating system delivers three 0.5 m³ of water tanks: one for household water, a second for the radiators and a third for the radiant floor. On the roof and a facade of the building there are PV panels with a total surface of 186 m² and a peak power of 17.1 kW. They are connected to a 7.2 kWh electric battery.

See also  Combination of air heat pumps for homes with air-geothermal heat exchangers – SPE

Control strategies

The scientists considered three control strategies to meet the thermal demand of the building: operation with priority in district heating; operation with priority in heat pumps; And only operate with district heating. The comparison was aimed at the thermal quantities, electrical energy consumption and production, the costs of energy and the environmental impact.

The simulation has taken into account that the annual thermal demand of buildings is 26,240 kWh for domestic hot water and 42,067 kWh for space heating. In the case of the DH priority, the district heating supplied 39.189 kWh, the HPS 27,099 kWh, with a monthly performance companies (COP) from 2.2 to 3.4, and the electric heating supplied 4,361 kWh.

On the other hand, when the strategy for the priority control of the heat pump was used, DH 16,406 kWh, the electric heating, had a negligible contribution and the heat pumps made 54,346 kWh with a cop with a cop ranging from 2.2 to 4. Finally, he delivered 70.9, while only district heating was used,, while only district heating was used,, while only district heating was used,, while only district heating was used,,, while only heating heating was used.

Result

“The annual photovoltaic Array -OverToplige energy is equal to 10,934 kWh. It is high during hot months and low during cold months. In the control strategy with district heating priority, 1,603 kWh of this excess energy has the potentially to provide the heat pumps in a 14.8% reduction in electricity, which results in a 14.8% reduction in the electricity consumption in a 14.8″%. ” the team added. “In the control strategy with heat pumps priority, 2,805 KHE of this excess energy have the potential to provide power to the heat pumps, resulting in a 13.5% reduction in the electricity consumption of heat pumps.”

See also  Perovskiet solar cells in underwater environments shows surprising efficiency results - PV Magazine International

According to the results, the annual costs for district heating and electricity were € 2,627 ($ 3,081), € 4,348 and € 6,312 for the priority of the heat pump, district heating priority and district heating only control strategies, respectively. They had 7,865 kg respectively, 13,716 kg and 21,854 kg CO2 equivalent emissions.

The researchers concluded that the use of HPS as the primary heat source in buildings with multiple apartment was the “most useful solution” in terms of operating costs and environmental impact.

Their findings were presented in “Analysis of a hybrid heating system with TRNSYS: district heating, heat pumps and photovoltaic in a building with several apartments“Published in Energy and buildings. Researchers from Greece for Research & Technology Hellas/Chemical Process and Energy Resources Institute (Certh/CPERI), Spain’s Fundacion Cartif and Sweden’s Rise Research Institutes of Sweden participated in the study.

This content is protected by copyright and may not be reused. If you want to work with us and reuse part of our content, please contact: editors@pv-magazine.com.

Popular content

Source link

Buildings combining District heat Heating International magazine MultiapartmentPV pumps PVpowered
Share. Facebook Twitter Pinterest LinkedIn Tumblr Email
solarenergy
  • Website

Related Posts

Mitsubishi Electric Trane announces new heat pump line for hydronic heating – SPE

March 6, 2026

Oleic acid anti-pollution coating for solar panels – SPE

March 5, 2026

Ground-mounted test field for Perovksite solar panels goes online in China – SPE

March 5, 2026
Leave A Reply Cancel Reply

Don't Miss
Technology

Australian-made vanadium flow battery project could see storage costs of $166/MWh – SPE

By solarenergyNovember 7, 20240

Australian Vanadium Limited (AVL) has advanced a vanadium flow battery (VFB) project to the design…

Hexa Renewables, Marubeni partner for 100 MW Solar in Japan – PV Magazine International

March 8, 2025

Letter from Chinese PV Industry: Energy China signs 5 GW EPC deal in Saudi Arabia

October 17, 2025

Accurate coupling values ​​mean less time spent on O&M later

May 6, 2025
Stay In Touch
  • Facebook
  • Twitter
  • Pinterest
  • Instagram
  • YouTube
  • Vimeo
Our Picks

Mitsubishi Electric Trane announces new heat pump line for hydronic heating – SPE

March 6, 2026

Origis is developing a 413 MW solar portfolio in West Texas

March 6, 2026

New Jersey expands state community solar program by 3 GW

March 6, 2026

How to address imbalance datasets in solar panel dust detection

March 5, 2026
Our Picks

Mitsubishi Electric Trane announces new heat pump line for hydronic heating – SPE

March 6, 2026

Origis is developing a 413 MW solar portfolio in West Texas

March 6, 2026

New Jersey expands state community solar program by 3 GW

March 6, 2026
About
About

Stay updated with the latest in solar energy. Discover innovations, trends, policies, and market insights driving the future of sustainable power worldwide.

Subscribe to Updates

Get the latest creative news and updates about Solar industry directly in your inbox!

Facebook X (Twitter) Instagram Pinterest
  • Contact
  • Privacy Policy
  • Terms & Conditions
© 2026 Tsolarenergynews.co - All rights reserved.

Type above and press Enter to search. Press Esc to cancel.