Close Menu
  • News
  • Industry
  • Solar Panels
  • Commercial
  • Residential
  • Finance
  • Technology
  • Carbon Credit
  • More
    • Policy
    • Energy Storage
    • Utility
    • Cummunity
What's Hot

Dutch solar owners asked to switch off during peak periods to ease the distribution crisis

June 7, 2026

The hydrogen flow: Toyota demonstrates its racing prototype on liquid hydrogen

June 7, 2026

Era of electrification exposing Australia’s weakest link

June 6, 2026
Facebook X (Twitter) Instagram
Facebook X (Twitter) Instagram
Solar Energy News
Monday, June 8
  • News
  • Industry
  • Solar Panels
  • Commercial
  • Residential
  • Finance
  • Technology
  • Carbon Credit
  • More
    • Policy
    • Energy Storage
    • Utility
    • Cummunity
Solar Energy News
Home - Technology - New design strategy for PV systems avoids oversizing and curtailment – ​​SPE
Technology

New design strategy for PV systems avoids oversizing and curtailment – ​​SPE

solarenergyBy solarenergyMay 15, 2024No Comments4 Mins Read
Facebook Twitter Pinterest LinkedIn Tumblr Email
Share
Facebook Twitter LinkedIn Pinterest Email

A group of scientists in Thailand have outlined a new approach to preventing oversizing and overvoltage in energy markets by applying volt-watt droop mitigation strategies. The new methodology leads to a reduction in the net present value of a PV system, but also increases the levelized energy costs.

May 14, 2024 Emiliano Bellini

Researchers from King Mongkut’s University of Technology North Bangkok in Thailand have proposed a new methodology to conduct techno-economic assessments of distributed PV systems taking into account surge-induced curtailment.

The scientists emphasized that, unlike previous methods for sizing PV systems, the new approach is not intended to identify the optimal size of a solar panel based on profit maximization and self-consumption policies. They previously suggested avoiding oversizing and “exaggerated profitability,” but said this choice leads to significantly improved levelized energy costs (LCOE), especially in scenarios where curtailment is expected to increase, due to higher penetration of renewables .

The research group conducted a sensitivity analysis to assess the impact of different voltage thresholds of overvoltage-induced production curtailment on the techno-economic performance of distributed PV systems, based on the electricity tariffs set by the Metropolitan Electricity Authority (MEA) in Thailand.

The academics monitored the load for a full year in 2018 and found that the maximum load was at 9 p.m., with consumption being highest in April. “As a result, air cooling loads increased significantly,” they explained. “The load tended to decrease when the season changed from summer (March to May) to winter (November to February). The lowest load was observed in December as the temperature was generally pleasant, significantly reducing the air cooling load.”

See also  British startup unveils industrial heat pump for hot water and steam generation – SPE

Electricity prices in the analyzed area ranged from $0.176/kWh to $0.057/kWh and a volt-watt droop mitigation strategy was assumed to be implemented. This method requires the deployment of an additional controller at the point of common coupling (PCC) and is generally used for local PV power limitation. “This strategy limits PV generation when the voltage reaches the 1.06 pu threshold, according to ANSI C84.1-2016, IEEE 1547-2018 and IEC 60038-2009 standards,” the researchers specified.

Their analysis took into account techno-economic parameters such as self-consumption rate (SCR), self-sufficiency rate (SSR), net present value (NPV) and LCOE.

They also adopted the so-called Jiménez-Castillo Approach to the optimization of PV system sizing, which aims at maximizing NPV values, and considers four different scenarios: Scenario 0, where overvoltage and curtailment are neglected; Scenario 1, where overvoltage-induced production limitation and the location of PV installations are taken into account and PV systems are installed at each node in each area; Scenario 2, where PV systems are installed on each node in two areas; and Scenario 3, where PV systems are installed at every node in every area of ​​the feeder.

Through this assessment, the scientists found that to prevent short circuits and overvoltages, the size of the PV system could be reduced by up to 58.33%, depending on the number of PV systems and their location. This would lead to a reduction in the NPV of 21.34%, but also to an increase in the LCOE of 22.96%.

“Additionally, the findings indicate that the SCR increased slightly by up to 11%, but the SSR decreased marginally by up to 4% upon the implementation of surge-induced production cuts,” she added. “Ultimately, the sensitivity analysis showed that the optimal PV power remained unchanged, even though different voltage thresholds were applied. However, the NPV decreased significantly, by as much as 25%, and the LCOE increased by as much as 20.72%, while the voltage threshold decreased to 1.01 pu. The SCR tended to increase by about 10%, while the SSR remained unchanged.”

See also  Assessment of Nigeria's Agrivoltaic Potential Identifies Northern States as Optimal Areas – SPE

Their findings are available in the study “Techno-economic assessment of grid-connected residential photovoltaic systems considering overvoltage-induced curtailment of generation”, which was recently published in Energy reports.

This content is copyrighted and may not be reused. If you would like to collaborate with us and reuse some of our content, please contact: editors@pv-magazine.com.

Source link

avoids curtailment design oversizing SPE strategy systems
Share. Facebook Twitter Pinterest LinkedIn Tumblr Email
solarenergy
  • Website

Related Posts

Pexapark registers 17 European PPAs for 966 MW in April – SPE

May 27, 2026

Saudi Arabia gets first BESS production facility – SPE

May 27, 2026

Seven countermeasures against negative electricity prices – SPE

May 26, 2026
Leave A Reply Cancel Reply

Don't Miss
Policy

Brazil to add 11.4 GW of solar by 2025 despite regulatory hurdles – SPE

By solarenergyDecember 11, 20250

Brazilian photovoltaic association ABSolar says solar capacity expansion could fall by 24% from 15 GW…

Insurers warn of supply chain tensions and stricter OEM warranties in battery sector – SPE

November 8, 2025

Seeing double the solar installations in Oregon | Projects Weekly

February 10, 2026

NJ Governor Signs Bill to Expedite Residential Solar Permitting

January 7, 2026
Stay In Touch
  • Facebook
  • Twitter
  • Pinterest
  • Instagram
  • YouTube
  • Vimeo
Our Picks

Dutch solar owners asked to switch off during peak periods to ease the distribution crisis

June 7, 2026

The hydrogen flow: Toyota demonstrates its racing prototype on liquid hydrogen

June 7, 2026

Era of electrification exposing Australia’s weakest link

June 6, 2026

‘Come out from behind your screen, our industry is ultimately about people’

June 6, 2026
Our Picks

Dutch solar owners asked to switch off during peak periods to ease the distribution crisis

June 7, 2026

The hydrogen flow: Toyota demonstrates its racing prototype on liquid hydrogen

June 7, 2026

Era of electrification exposing Australia’s weakest link

June 6, 2026
About
About

Stay updated with the latest in solar energy. Discover innovations, trends, policies, and market insights driving the future of sustainable power worldwide.

Subscribe to Updates

Get the latest creative news and updates about Solar industry directly in your inbox!

Facebook X (Twitter) Instagram Pinterest
  • Contact
  • Privacy Policy
  • Terms & Conditions
© 2026 Tsolarenergynews.co - All rights reserved.

Type above and press Enter to search. Press Esc to cancel.