Close Menu
  • News
  • Industry
  • Solar Panels
  • Commercial
  • Residential
  • Finance
  • Technology
  • Carbon Credit
  • More
    • Policy
    • Energy Storage
    • Utility
    • Cummunity
What's Hot

Dutch solar owners asked to switch off during peak periods to ease the distribution crisis

June 7, 2026

The hydrogen flow: Toyota demonstrates its racing prototype on liquid hydrogen

June 7, 2026

Era of electrification exposing Australia’s weakest link

June 6, 2026
Facebook X (Twitter) Instagram
Facebook X (Twitter) Instagram
Solar Energy News
Sunday, June 7
  • News
  • Industry
  • Solar Panels
  • Commercial
  • Residential
  • Finance
  • Technology
  • Carbon Credit
  • More
    • Policy
    • Energy Storage
    • Utility
    • Cummunity
Solar Energy News
Home - Solar Industry - Dynamic modeling for building-integrated photovoltaic-thermal systems
Solar Industry

Dynamic modeling for building-integrated photovoltaic-thermal systems

solarenergyBy solarenergyJune 20, 2024No Comments4 Mins Read
Facebook Twitter Pinterest LinkedIn Tumblr Email
Share
Facebook Twitter LinkedIn Pinterest Email

Researchers in the Middle East have conducted a series of simulations to assess the technical and economic feasibility of building-integrated photovoltaic-thermal systems. The proposed framework could be applicable to different building types and geographic locations.

June 20, 2024 Lior Kahana

Researchers from Jordan’s Al al-Bayt University have developed comprehensive theoretical dynamic models to analyze the performance of integrated photovoltaic thermal (BIPV/T) systems.

The scientists tested their new framework through a series of simulations conducted on a residential building in the north-central city of Mafraq in Jordan. They optimized the BIPV/T system to maximize output and efficiency while minimizing panel area.

“Mafraq is one of the most suitable regions in Jordan for harnessing the potential of solar energy and implementing solar thermal energy installations,” the academics said. “It has a daily mean direct normal irradiance (DNI) ranging from 6.54 to 7.29 kWh/m2 and an annual mean wind speed of 4.72 m/s, enjoying abundant solar radiation and abundant wind resources.”

The building was simulated with MATLAB/Simulink. It had a roof area of ​​200 m2, with a hot water requirement supplied by the thermal part of the panels of 10 m3 per month. The average electricity demand for winter, spring, summer and autumn was 452 kWh, 582 kWh, 443 kWh, 342 kWh and 441 kWh, respectively.

It was assumed that the BIPV/T panels would each have a power of 320 W and an efficiency of 16.49%. The hourly solar radiation and ambient temperature data fed to the model comes from an artificial neural network (ANN) developed by the group. According to the researchers, the model achieves high accuracy values ​​of more than 0.97 for the predicted solar irradiance during training, validation, testing and the overall dataset.

See also  Tigo Energy MLPE now compatible with Sonnen Inverter-Battery systems

“The comprehensive ANN-based modeling and optimization approach can help policymakers and energy professionals analyze within reasonable domain time and with good accuracy, accelerating design and performance improvement-based analyzes and tasks,” the team said.

For the optimization task, the group chose the Non-Dominated Genetic Sorting Algorithm II (NSGA-II), while also integrating the Preference Order by Similarity to the Ideal Solution (TOPSIS) technique. NSGA-II optimizes multiple objectives by ranking solutions based on dominance, while TOPSIS ranks options by comparing their closeness to the best and worst possible solutions.

The analysis showed that the optimal solution for winter involves the installation of 15 modules, with an electrical power of 2,606 W, a thermal power of 5,569 W and a total electricity produced of 21.95 kWh. In summer, the optimal solution is 16 modules with an electrical power of 1,780 W, a thermal power of 4,700 W and a total electricity produced of 23.63 kWh. 12 BIPV/T modules were required for the spring seasons and 14 in the fall.

The scientists also conducted an economic analysis. In this analysis, they assumed that the BIPV/T would last 20 years, that the interest rate would be 5%, and that the variable operating costs for the system would be $0.1/kWh. In addition, the base cost was set at $1,067 for the hot water storage tank, $180/kW for the inverter and controller, and $200/m2 for the BIPV/T panels.

Under these conditions, the levelized energy cost (LCOE) was found to be $0.1/kW. If equipment costs increase by 20%, the LCOE will reach $0.12/kW, while if it increases by 40%, the price will reach $0.14/kW. If equipment prices fall by 20%, the LCOE is $0.08/kW, and if they fall by 40%, the cost is $0.06/kW.

See also  Above-ground agrivoltaics could disrupt global navigation satellite systems used for precision agriculture – SPE

“The findings indicate that the proposed framework may be applicable to different building types and geographic locations. Consequently, it has significant value in promoting the use of solar energy with optimal energy, economic and environmental performance,” the academics concluded.

The results are presented in “Energy and economic analysis of an integrated photovoltaic thermal system in buildings: seasonal dynamic modeling supported by a machine learning-assisted method and multi-objective genetic optimization,” published in Alexandria Engineering Journal.

The team also included scientists from King Fahd University of Petroleum & Minerals in Saudi Arabia, University College London in Britain, the University of Durham and the University of Engineering and Technology in Pakistan.

This content is copyrighted and may not be reused. If you would like to collaborate with us and reuse some of our content, please contact: editors@pv-magazine.com.

Source link

buildingintegrated Dynamic modeling photovoltaicthermal systems
Share. Facebook Twitter Pinterest LinkedIn Tumblr Email
solarenergy
  • Website

Related Posts

ComEd starts a new energy pilot with a solar rebate on the roof of a brewery

June 5, 2026

Video: Understanding Safe Harbor Programs | Power forward!

June 3, 2026

Illinois board approves massive Pride of the Prairie site | Projects Weekly

June 1, 2026
Leave A Reply Cancel Reply

Don't Miss
Policy

DOE cancels $83 billion in clean energy loans

By solarenergyJanuary 23, 20260

The Ministry of Energy announced on Thursday that it is pulling the plug on $83.6…

BYD launches its first integrated home storage system – PV Magazine International

March 18, 2025

What are the selling points of marine energy? – SPE

March 27, 2026

How to balance energy losses and cost-effectiveness in PV-BESS powered EV charging stations – SPE

November 20, 2025
Stay In Touch
  • Facebook
  • Twitter
  • Pinterest
  • Instagram
  • YouTube
  • Vimeo
Our Picks

Dutch solar owners asked to switch off during peak periods to ease the distribution crisis

June 7, 2026

The hydrogen flow: Toyota demonstrates its racing prototype on liquid hydrogen

June 7, 2026

Era of electrification exposing Australia’s weakest link

June 6, 2026

‘Come out from behind your screen, our industry is ultimately about people’

June 6, 2026
Our Picks

Dutch solar owners asked to switch off during peak periods to ease the distribution crisis

June 7, 2026

The hydrogen flow: Toyota demonstrates its racing prototype on liquid hydrogen

June 7, 2026

Era of electrification exposing Australia’s weakest link

June 6, 2026
About
About

Stay updated with the latest in solar energy. Discover innovations, trends, policies, and market insights driving the future of sustainable power worldwide.

Subscribe to Updates

Get the latest creative news and updates about Solar industry directly in your inbox!

Facebook X (Twitter) Instagram Pinterest
  • Contact
  • Privacy Policy
  • Terms & Conditions
© 2026 Tsolarenergynews.co - All rights reserved.

Type above and press Enter to search. Press Esc to cancel.