Close Menu
  • News
  • Industry
  • Solar Panels
  • Commercial
  • Residential
  • Finance
  • Technology
  • Carbon Credit
  • More
    • Policy
    • Energy Storage
    • Utility
    • Cummunity
What's Hot

New Mexico opens $ 5.3 million commercial Energy Efficiency Program

June 7, 2025

Solar -Wafer prices have fallen 22.78% since April peak

June 7, 2025

China’s XYZ launches 261 kWh immersion-cooled commercial battery-PV Magazine International

June 7, 2025
Facebook X (Twitter) Instagram
Facebook X (Twitter) Instagram
Solar Energy News
Saturday, June 7
  • News
  • Industry
  • Solar Panels
  • Commercial
  • Residential
  • Finance
  • Technology
  • Carbon Credit
  • More
    • Policy
    • Energy Storage
    • Utility
    • Cummunity
Solar Energy News
Home - Technology - New approach for estimating containment and loss losses in hybrid wind-solar installations – SPE
Technology

New approach for estimating containment and loss losses in hybrid wind-solar installations – SPE

solarenergyBy solarenergyAugust 10, 2024No Comments4 Mins Read
Facebook Twitter Pinterest LinkedIn Tumblr Email
Share
Facebook Twitter LinkedIn Pinterest Email

A European research team has proposed a new methodology for optimal design of hybrid wind-solar power plants. Their approach is based on 1-minute resolution data, which the scientists say provides much more accurate information about potential curtailment and clipping losses compared to 1-hour resolution data.

August 9, 2024 Lior Kahana

A European research team has investigated the effect of different time resolution data on the design of hybrid PV-wind power plants (HyPPs) and found that lower resolution can result in an overestimation of the net present value (NPV) of the facilities by up to 3%.

“When conducting feasibility studies for HyPPs, hourly resolution data or lower are typically used as this is the resolution commonly available in meteorological databases,” the group said. “However, when optimizing the topology of HyPPs with capacity limits at the point of interconnection (POI), the techno-economic feasibility of these power plants could be overestimated, as the curtailment and clipping losses will be underestimated when using hourly data instead of higher resolution data.”

The study was based on data obtained from an operational HyPP in East Germany. This plant has an installed PV capacity of 11.64 MW and a DC-AC ratio of 1.13. The wind turbines have an installed capacity of 24 MW and because they are installed 1.6 km from the PV panels, they do not cast any shadows. In 2020, the year in which the researchers conducted their research, the wind and PV installations generated 57.58 GWh and 12.80 GWh respectively.

Weather and generation data from the German HyPP were recorded at 5 second resolution and downsampled for one minute and one hour for the comparative analysis. As part of the analysis, different DC-AC ratios have been assumed for the PV portion, effectively changing the actual capacity of the plant.

See also  Australian communities oppose major renewables – SPE

“It has been shown that for a HyPP consisting of 1 wind, PV and POI capacity per unit (pu) respectively, the curtailment losses are estimated to be only 1.45% for the 5 seconds and 1.09% for the 1 hour. resolution dataset, which translates into income losses of 0.77% and 0.51% respectively in the German day-ahead market,” they found. “These results demonstrate a discrepancy between the losses estimated by the hourly and high-resolution data sets.”

Furthermore, the researchers found that using 1-minute resolution data appears sufficient to approximate the containment losses predicted by the 5-second data set. “Acquiring the data at 1-minute resolution seems to be a good compromise between accuracy and measurement effort,” they explained.

When conducting a techno-economic estimation to find the optimal size of the HyPP, the researchers found that using the 1-hour data set leads to a 1.86% overestimation of the total NPV compared to the 1-hour data set minute. They also said that this overestimation increases when the shares of PV and wind capacities are further increased relative to POI capacity.

“The techno-economic model indicates that the cost-optimal HyPP topology for this location consists of wind and PV capacities that are each slightly greater than, but still closely match, the POI capacity. Using the 1-hour instead of 1-minute resolution data appears to have little impact on identifying the optimal HyPP design,” they say. “However, for the optimal HyPP topology derived from the 1-hour data set, the NPV is overestimated by 2.99% when calculated using the 1-hour data set instead of the 1-minute data set.”

See also  Italy prepares energy storage auctions – SPE

Their findings were presented in “Influence of high-resolution data on accurate mitigation damage estimation and optimal design of hybrid PV-wind power plants”, published on Applied energy. The group included academics from the Norwegian Institute of Energy Technology (IFE), the University of Oslo (UiO) and the German Fraunhofer Institute for Solar Energy Systems (ISE).

This content is copyrighted and may not be reused. If you would like to collaborate with us and reuse some of our content, please contact: editors@pv-magazine.com.

Source link

approach containment Estimating hybrid installations loss losses SPE windsolar
Share. Facebook Twitter Pinterest LinkedIn Tumblr Email
solarenergy
  • Website

Related Posts

China’s XYZ launches 261 kWh immersion-cooled commercial battery-PV Magazine International

June 7, 2025

HoarFrost-inspired technology to improve MPPT in PV systems under partial Shadow-PV Magazine International

June 6, 2025

New pollution room for testing dust structure in solar modules – PV Magazine International

June 6, 2025
Leave A Reply Cancel Reply

Don't Miss
News

Arevon is breaking ground on a 228 MW solar project in Indiana

By solarenergyMay 20, 20240

Arevon Energy, along with CenterPoint Energy, Bechtel, participating landowners and other guests, gathered at a…

Rooftop solar rates in Australia fall below linear average – SPE

October 8, 2024

Sunrun, PG&E Launch VPP to resolve California Grid restrictions

March 26, 2025

‘No good thinking’: Zenobē on the LDES -CAP and floor schedule

May 2, 2025
Stay In Touch
  • Facebook
  • Twitter
  • Pinterest
  • Instagram
  • YouTube
  • Vimeo
Our Picks

New Mexico opens $ 5.3 million commercial Energy Efficiency Program

June 7, 2025

Solar -Wafer prices have fallen 22.78% since April peak

June 7, 2025

China’s XYZ launches 261 kWh immersion-cooled commercial battery-PV Magazine International

June 7, 2025

Don’t let the Congress undo the energy progress of West Virginia

June 7, 2025
Our Picks

New Mexico opens $ 5.3 million commercial Energy Efficiency Program

June 7, 2025

Solar -Wafer prices have fallen 22.78% since April peak

June 7, 2025

China’s XYZ launches 261 kWh immersion-cooled commercial battery-PV Magazine International

June 7, 2025
About
About

Stay updated with the latest in solar energy. Discover innovations, trends, policies, and market insights driving the future of sustainable power worldwide.

Subscribe to Updates

Get the latest creative news and updates about Solar industry directly in your inbox!

Facebook X (Twitter) Instagram Pinterest
  • Contact
  • Privacy Policy
  • Terms & Conditions
© 2025 Tsolarenergynews.co - All rights reserved.

Type above and press Enter to search. Press Esc to cancel.